Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arch. cardiol. Méx ; 86(2): 123-129, abr.-jun. 2016. tab, graf
Article in Spanish | LILACS | ID: biblio-838361

ABSTRACT

Resumen Los resultados a largo plazo del procedimiento de maze con criotermia en pacientes con fibrilación auricular durante procedimientos quirúrgicos concomitantes son todavía inciertos. Método Entre 2006 y 2011, 150 pacientes consecutivos con fibrilación auricular persistente y cardiopatía asociada fueron sometidos a cirugía de ablación mediante criotermia asociada a cirugía concomitante. El procedimiento de Cox-Maze biauricular fue realizado en 67 pacientes y ablación aislada de la aurícula izquierda en 83 pacientes. Los resultados a tres años en estos grupos fueron comparados mediante seguimiento clínico, electrocardiográfico y mediante Holter 24 horas y ecocardiografía con medición de la onda A transmitral al mes, a los 6 y 12 meses y después anualmente. Resultados Los pacientes sometidos a ablación Cox-Maze presentaron una libertad de fibrilación auricular del 97, 94, 89, 80 y 54% a 1, 6, 12, 24 y 36 meses respectivamente. En el seguimiento de los 12 meses estas diferencias resultaron significativas (p < 0.05). Como factor de riesgo de recurrencia de fibrilación auricular se identificó la ablación aislada de la aurícula izquierda. Conclusiones La ablación mediante criotermia tiene un elevado porcentaje de éxitos a dos años; la recurrencia se incrementa a partir de entonces independientemente de la técnica realizada. Para el tratamiento de la fibrilación auricular persistente asociada a otra patología quirúrgica cardiaca se debe realizar un tratamiento intensivo mediante ablación biauricular.


Abstract The long-term results of cryomaze in patients with longstanding persistent atrial fibrillation during concomitant surgical procedures are still uncertain. Methods Between 2006 and 2011, 150 consecutive patients with associated long-lasting permanent atrial fibrillation and associated heart disease underwent heart surgery were treated by biatrial Cox-Maze (63 patients) or by isolated endocardial or epicardial left atrial cryoablation (83 patients) concomitantly. The results at 3 years in these groups were compared with clinical monitoring, electrocardiography, 24-hour Holter, and echocardiography with measurement of the transmitral A wave at 1, 6 and 12 months and annually thereafter in all patients. Results Patients undergoing Cox-Maze IV ablation presented rates of freedom from atrial fibrillation of 97, 94, 89, 80 and 54% at 1, 6, 12, 24 and 36 months, respectively. In the 12-month follow-up, these differences were significant (p < .05). The independent risk factors of atrial fibrillation recurrence was isolated ablation of left atrium. Conclusions Atrial fibrillation by cryothermia ablation had a high success rate before 2 years postoperatively. Recurrence of atrial fibrillation increased thereafter regardless of the technique used, although it was more intense and developed earlier in cases of monoatrial ablation. For the treatment of other long-lasting permanent atrial fibrillation cardiac surgery-associated pathology, an aggressive biatrial treatment with Cox maze ablation should be performed.


Subject(s)
Humans , Male , Female , Aged , Atrial Fibrillation/surgery , Cryosurgery/methods , Heart Atria/surgery , Recurrence , Time Factors , Prospective Studies , Cardiac Surgical Procedures/methods
2.
Rev. colomb. ortop. traumatol ; 18(1): 57-61, mar. 2004. ilus
Article in Spanish | LILACS | ID: lil-619202

ABSTRACT

Se elaboró un trabajo de tipo experimental en el cual se planteó como objetivo esencial el diseño de un instrumental para fijación anterior de columna que reuniera las normas mínimas de biocompatibilidad, versatilidad en su aplicación y resistencia a las cargas mecánicas reportadas en la literatura como válidas para este tipo de elementos. Para hacer el diseño del instrumento se revisó la literatura acerca de los sistemas existentes en el mercado, tanto aquellos de uso rutinario como los de tipo experimental, y se buscó adecuar un sistema nuevo que cumpliera con especificaciones mínimas, pero que a la vez fuera de bajo costo y fácil aplicación. El proceso de investigación fue desarrollado en tres fases.


Subject(s)
Lumbar Vertebrae , Orthopedic Fixation Devices , Spine
SELECTION OF CITATIONS
SEARCH DETAIL